Fast and Accurate Neonatal Jaundice Screening
The BM-100A Jaundice Detector is an advanced transcutaneous bilirubin measurement device developed to assist healthcare professionals in the early screening and monitoring of neonatal jaundice. By providing quick, non-invasive bilirubin measurements, the device supports clinical decision-making while helping reduce unnecessary blood sampling.
Its intelligent operating system, colour touchscreen, and rapid measurement capability make it an excellent choice for busy maternity hospitals, neonatal intensive care units, paediatric departments, and newborn care centres.
The BM-100A combines accuracy, efficiency, and portability, making routine neonatal jaundice screening faster and more convenient.
Non-Invasive Bilirubin Measurement
The BM-100A measures bilirubin levels through the skin using advanced optical technology, allowing healthcare professionals to screen newborns without the need for invasive blood collection during routine assessments.
Benefits include:
- Rapid bilirubin screening
- Non-invasive measurement
- Comfortable for newborns
- Immediate results
- Supports neonatal jaundice assessment
- Suitable for repeated monitoring
- Improves workflow efficiency
Key Features
Features Include
- Transcutaneous bilirubin measurement
- 3.0-inch colour touchscreen
- Large digital display
- Intelligent patient data management
- Multiple patient information storage
- Average measurement function
- Rechargeable lithium battery
- Charging base included
- Xenon flash measurement technology
- Long-life flash lamp
- Integrated light checker
- Dual measurement units
- Fast measurement
- Portable handheld design
Intelligent Data Management
The BM-100A simplifies neonatal monitoring with built-in patient information management.
Functions include:
- Storage of multiple patient records
- Multiple measurement history
- Easy patient identification
- Efficient data review
- Streamlined neonatal monitoring
- Simplified clinical workflow
This intelligent system helps clinicians organise patient information while improving efficiency in busy neonatal departments.
High Accuracy with Average Measurement
To improve measurement reliability, the BM-100A offers an average measurement function.
Advantages include:
- Adjustable averaging (1–5 measurements)
- Improved measurement consistency
- Enhanced clinical confidence
- Reliable bilirubin assessment
- Reduced measurement variability
This feature supports accurate newborn screening in accordance with clinical practice.
Long Battery Life and Low Maintenance
The BM-100A is designed for continuous clinical use.
Key advantages include:
- Rechargeable battery
- Approximately 2,000 measurements per full charge
- Long-life xenon flash lamp
- Flash lamp lifespan of 150,000+ measurements
- Charging base included
- Integrated calibration light checker
- No consumables required for routine light checking
- Reduced operating costs
Easy-to-Read Colour Touchscreen
The large 3.0-inch colour touch display provides clear visibility of measurement results.
Features include:
- Touchscreen operation
- Large numeric display
- Fast result viewing
- User-friendly interface
- Easy navigation
- Rapid access to stored patient data
Dual Measurement Units
The BM-100A supports two commonly used bilirubin measurement units:
- mg/dL
- μmol/L
Users can easily switch between units to meet local clinical preferences and reporting requirements.
Technical Specifications
| Product Name | Jaundice Detector |
| Model | BM-100A |
| Measurement Method | Transcutaneous Bilirubin Measurement |
| Display | 3.0-inch Colour Touchscreen |
| Measurement Display | Large Digital Characters |
| Patient Data Storage | Multiple Patient Records |
| Average Measurement | 1–5 Measurements |
| Battery | Rechargeable |
| Battery Capacity | Approximately 2,000 Measurements per Charge |
| Flash Technology | Xenon Flash Lamp |
| Flash Lamp Life | ≥150,000 Measurements |
| Charging Base | Included |
| Calibration | Integrated Light Checker |
| Measurement Units | mg/dL / μmol/L |
| Application | Neonatal Jaundice Screening |
Applications
Ideal for:
- Neonatal Intensive Care Units (NICU)
- Hospitals
- Maternity Wards
- Paediatric Clinics
- Birth Centres
- Neonatal Care Units
- Community Healthcare Facilities
- Children’s Hospitals
- Medical Universities
- Maternal and Child Healthcare Centres
Benefits
Advantages Include
- Fast non-invasive bilirubin screening
- High measurement accuracy
- Colour touchscreen interface
- Intelligent patient management
- Long battery life
- Large internal data storage
- Long-life xenon flash lamp
- No consumables for light checking
- Portable handheld operation
- Suitable for routine neonatal screening
- Professional hospital performance
Why Choose Premium Medical Equipment Innovations?
Premium Medical Equipment Innovations supplies professional neonatal equipment, diagnostic devices, paediatric medical equipment, hospital instruments, and healthcare technology throughout South Africa and Africa.
We proudly supply:
- Public Hospitals
- Private Hospitals
- Neonatal Intensive Care Units
- Maternity Hospitals
- Paediatric Clinics
- Children’s Hospitals
- Government Healthcare Facilities
- Healthcare Procurement Teams
- Medical Universities
- Maternal and Child Healthcare Centres
Our neonatal diagnostic equipment is selected for accuracy, reliability, ease of use, and long-term clinical performance.
Request a Quote
Looking for a Jaundice Detector in South Africa?
Premium Medical Equipment Innovations supplies the BM-100A Transcutaneous Jaundice Detector to hospitals, maternity wards, neonatal intensive care units, paediatric clinics, and healthcare providers throughout South Africa and Africa.
Contact us today for pricing, availability, and bulk procurement enquiries.









Reviews
There are no reviews yet.