Infant and Neonatal T-Piece Resuscitator
The NEO-I T Piece Resuscitator is a manually operated, gas-powered resuscitation device designed to provide controlled respiratory support for newborns and infants weighing up to 10 kg.
Designed for neonatal and infant resuscitation, the NEO-I provides controllable Peak Inspiratory Pressure (PIP) and consistent Positive End-Expiratory Pressure (PEEP).
The unit requires no electrical power supply, making it suitable for delivery rooms, neonatal intensive care units (NICUs), nurseries, and appropriately equipped patient transport environments.
What Is a T-Piece Resuscitator?
A T-piece resuscitator is a gas-powered device used by trained healthcare professionals to provide controlled positive-pressure ventilation during neonatal and infant resuscitation.
Unlike manual resuscitation bags, where delivered pressure can vary with operator technique, a T-piece system allows clinicians to set controlled pressure settings.
The NEO-I is designed to provide adjustable PIP and PEEP, helping clinicians deliver controlled respiratory support in accordance with appropriate neonatal resuscitation protocols.
Key Features of the NEO-I
- Manually operated T-piece resuscitator
- Pneumatically driven
- No electrical power supply required
- Designed for newborns and infants up to 10 kg
- Particularly suitable for premature infants
- Adjustable Peak Inspiratory Pressure (PIP)
- Adjustable Positive End-Expiratory Pressure (PEEP)
- Adjustable maximum pressure
- Supports medical air/oxygen gas supply
- Integrated pressure manometer
- Compact clinical design
- Suitable for delivery rooms
- Suitable for NICU environments
- Suitable for nurseries
- Can be used in appropriate transport settings
- Designed for professional clinical use
Controlled PIP and PEEP
A major advantage of a T-piece resuscitator is the ability to provide controlled respiratory pressures.
The NEO-I allows clinicians to establish:
PIP – Peak Inspiratory Pressure
PIP is the maximum airway pressure delivered during inspiration.
PEEP – Positive End-Expiratory Pressure
PEEP maintains positive pressure at the end of expiration and is an important component of neonatal respiratory support.
The ability to control these parameters makes T-piece resuscitation particularly useful in neonatal and premature infant care.
Gas-Powered Operation
The NEO-I is pneumatically driven and does not require an electrical power supply for operation.
It operates using an appropriate medical gas source, such as oxygen or an air/oxygen mixture.
This provides flexibility for use in:
- Delivery suites
- Neonatal intensive care units
- Nurseries
- Maternity wards
- Emergency neonatal care
- Appropriate patient transport environments
Designed for Neonatal and Infant Resuscitation
The NEO-I is intended for newborns and infants weighing up to 10 kg.
Its controlled pressure delivery makes it particularly relevant to premature and neonatal patients who require carefully managed respiratory support.
The device should be operated only by appropriately trained healthcare professionals according to the manufacturer’s instructions and applicable neonatal resuscitation protocols.
Technical Specifications
| Specification | Details |
| Product Name | NEO-I T Piece Resuscitator |
| Product Type | Infant T Piece Resuscitator |
| Operation | Manual / Pneumatic |
| Patient Range | Newborns & Infants up to 10 kg |
| Gas Supply | Medical Oxygen or Air/Oxygen Mixture |
| Oxygen Concentration | 21%–100%, depending on gas supply |
| Input Gas Flow | 5–15 L/min |
| Manometer Range | -10 to 80 cmH₂O |
| Manometer Accuracy | ±2% Full Scale |
| Maximum Pressure Range | 1–60 cmH₂O |
| PIP | Adjustable |
| PEEP | Adjustable |
| Electrical Supply | Not Required |
| Main Applications | Delivery Room, Nursery, NICU & Transport |
| Approx. Unit Size | 190 × 100 × 263 mm |
| Total Mass | ≤2 kg including accessories |
PIP Setting Range
The available PIP range varies according to gas flow:
| Gas Flow | Approximate PIP Range |
| 5 L/min | 1–57 cmH₂O |
| 8 L/min | 2–58 cmH₂O |
| 10 L/min | 3–59 cmH₂O |
| 15 L/min | 5–60 cmH₂O |
PEEP Setting Range
The available PEEP also varies according to gas flow and device configuration.
Clinical settings must always be established by appropriately trained personnel according to the patient’s requirements, applicable protocols, and the manufacturer’s operating instructions.
Where Is the NEO-I T Piece Resuscitator Used?
The NEO-I is suitable for professional neonatal care environments, including:
- Neonatal Intensive Care Units (NICU)
- Delivery rooms
- Labour and maternity wards
- Newborn nurseries
- Neonatal emergency departments
- Paediatric hospitals
- Appropriate neonatal transport
- Specialist maternity hospitals
Benefits of the NEO-I T Piece Resuscitator
Controlled Pressure Delivery
The device allows controlled PIP and PEEP settings rather than relying solely on manual compression technique.
No Electricity Required
Pneumatic operation means an electrical power connection is not required during use.
Suitable for Premature Infants
The system is specifically designed for neonatal and infant respiratory resuscitation, including premature infants within the specified patient range.
Compact Design
Its compact construction makes the device practical for delivery rooms, neonatal units, and appropriate transport applications.
Professional Neonatal Application
The NEO-I is purpose-designed for professional neonatal and infant resuscitation environments.
T Piece Resuscitator vs Manual Resuscitation Bag
Both devices can have roles in neonatal respiratory support, but their operation differs.
A T-piece resuscitator uses a continuous gas supply and allows controlled PIP and PEEP settings.
A manual resuscitation bag relies more directly on the operator squeezing the bag to deliver ventilation.
For neonatal applications where controlled and repeatable airway pressures are required, T-piece resuscitators provide clinicians with greater control over delivered pressure.
Request a Quote
Looking for a T-piece resuscitator for your hospital, maternity unit, or neonatal intensive care department?
Premium Medical Equipment Innovations supplies the NEO-I Infant T- Piece Resuscitator and other neonatal medical equipment to hospitals, clinics, maternity facilities and healthcare procurement organisations.
Contact us today for product availability, pricing, and bulk procurement enquiries.